0 Cart
Added to Cart
    You have items in your cart
    You have 1 item in your cart
    Total
    Check Out Continue Shopping

    The water supply valves need not be shut off but do NOT open the mixer valve until the installation is complete!

    Remove Spout Assembly

    • Remove short set screw (if applicable) - 2.5mm hex key.
    • Remove long set screw - 2.5mm hex key.
    • Pull spout straight up to remove - Caution: water will drain from base of spout.
    • Seat may have been left in faucet body - make certain it is removed.

    Clean Faucet Body

    Install Spout

    • Apply NSF-61 certified silicone grease to inside surface of faucet body.
    • Apply silicone grease to outside surfaces of seat, O-rings and retainer.
    • Rotate spout until cross-hole in retainer is aligned with cross-hole in faucet body.
    • Lower spout into faucet body, without rotating, until fully seated.
    • Use hex key to probe and verify cross-holes are aligned - Very Important
    • Screw long set screw into faucet body until seated against spout - Caution: set screw MUST pass through cross-hole in retainer and make contact with spout. Otherwise, water pressure will force the spout out of the faucet body when faucet is in use!
    • Rotate long set screw 1/2 turn counter-clockwise.
    • Screw short set screw (if applicable) into faucet body until firmly seated against long set screw.
    Back to the top