K1235 Hose and Wand Assembly - M70 & M65

K1235 Hose and Wand Assembly - M70 & M65

Water supply need not be shut off for this repair. Straight copper tube, barbed plastic tube and brass nut are not used for this repair.

Remove Hose

  • Pull hose from barbed check valve housing - cut black hose if necessary.
  • Remove plastic tube from flared copper.
  • Remove flared copper tube from hose.
  • Lift wand and remove hose from hose guide.

Reassemble

  • Insert hose down through hose guide and seat wand in hose guide.
  • Insert small end of 'U' shaped flared copper tube (apply detergent as lubricant) into small hose section approx 3/4".
  • Insert barbed end of check valve housing (apply detergent as lubricant), to shoulder, into large hose section.
  • Make certain check valve housing threads have not been loosened during repair.

Adjust Spray

  • Spray tube may be rotated to direct the spray as desired.
  • Loosen handle nut - pliers may be required – pad the jaws with a cloth to prevent scratches.
  • Adjust direction of spray to desired position by rotating spray tube.
  • Tighten nut just firmly enough to hold spray tube in desired position.